Product Description
To use as a Bi-Component product (all optional additives):
ESB2 Universal Stain Blocking: Designed to be used with
Universal Primer, UP-1000 only. Do not add
to any other products.
For gallon containers-Add 5 oz of ESB2 per
gallon of UP-1000*.
For 5 gallon pails. Add 25 oz of ESB2 per Pail
of UP-1000*.
*Shake immediately after adding ESB2 to
the UP-1000!
Pot life: The UP-1000 will have 2 weeks of pot
life after the addition of ESB2.
Note: Viscosity will increase slightly every few
days. Product may require a small reduction at
times with water to achieve the desired spray
viscosity. Typically no more than 5% by volume
of additional water is necessary.
Mixing Instructions:
Add the proper amount of ESB2 to the
container of UP-1000 and immediately mix by
placing in a commercial paint shaker or
incorporate with a propeller blade mixer for a
minimum of 5 minutes.
________________________________________________________________________________________
EWH5 Hardener: @ 5-10% by weight or
volume (6-12 oz per gallon) and mix
thoroughly.
Pot life: 1-2 hours depending on temperature.
NOTE: Adding hardener will increase the gloss
by approximately 3-5 degrees.
Adding hardener will also slow the speed of
cure slightly.
________________________________________________________________________________________
SOL-0090 Retarder: To improve flow and leveling or to
assist with coalescing at lower temperatures,
use SOL-0090 at levels not to exceed 4% by
volume (5 oz per gallon). Maximum VOC when
adding retarder as specified is < 275 grams per
liter.
SOL-0090 is used specifically for increasing the open time of waterborne coatings. In hot weather or adverse conditions (such as
areas of high heat or air flow), it will improve flow and leveling properties in coatings, and increase the open time and workability of
wiping stains and glazes.
________________________________________________________________________________________